Advanced search

Subfamily

   Without Tank
   02 liters Tank
   03 liters Tank
   05 liters Tank
   07 liters Tank
   08 liters Tank
   10 liters Tank
  • HYDROPUMP "AL-HPA-DE-25-VS-00-RL-PM-05AL-MD-LV-OR"
    AED-W6-4505
    HYDROPNEUMATIC PUMP type "AL-HPA-DE-25-VS-RL-PM with 14 cc / cycle double acting, actuated pneumatically. Pressure ratio 1:35 - Maximum pressure 250 bar - Max air pressure 7 bar. - 5 liter tank type MEDIUM in aluminum-plastic with oil level. - Pressure relief valve set at 100 bar (adjustable from 25 to 350 bar) - Hand pump GH-HPM20 for external manual operation - Tap lever 0-1 unstable NC for pump activation - Central tap 0-1 - Horizontal OR mounting - For DOUBLE EFFECT cylinders.
  • HYDROPUMP "AL-HPA-SE-12-VS-00-00-PM-03AL-MD-LV-OR"
    AED-Y1-3503
    HYDROPUMP tipo "AL-HPA-SE-12-VS-PM-03AL-MD-LV-OR" con 12 cc/ciclo a doppia mandata, azionata pneumaticamente - Rapporto di pressione 1:43 - Pressione massima 300 bar - Pressione massima aria 7 bar - Rubinetto di scarico con Valvola di Ritegno incorporata - Serbatoio da 3 litri tipo MEDIUM in alluminio-plastica con livello olio - Valvola di massima pressione tarata a 100 bar (regolabile da 25 a 350 bar) - Pompa a Mano GH-HPM20 di servizio esterna per azionamento manuale - Rubinetto principale - Per cilindri a SEMPLICE EFFETTO - Montaggio Orizzontale "OR"
  • HYDROPUMP "AL-HPA-SE-12-VS-00-RL-PM-03AL-MD-LV"
    AED-Y1-4103
    HydroPneumatic pump type "AL-HPA-SE-12-VS-RL-PM-S03AL-VR with 12 cc / cycle double acting, pneumatically operated - Pressure ratio of 1:35 - Max pressure 300 bar - Maximum pressure air 8 bar - MEDIUM tank 3-liter aluminum-plastic type with oil level. - Pressure relief valve set at 100 bar (adjustable from 25 to 350 bar) - External emergency hand pump for manual acting- HPM20 - Tap 0-1 unstable NC lever to activate the pump - tap root - For Hydraulic cylinders single effect - Vertical Mounted "VR
  • HYDROPUMP "AL-HPA-DE-12-VS-00-RL-PM-07AL-LG-LV"
    AED-Y6-4107
    Hydro pneumatic pump - 12 cc/rev double acting, pneumatically driven - Pressure ratio 1:43 - Max pressure 300 bar - Max air pressure 7 bar - Double effect distributor 4/2" - 7 liter aluminum-polymer tank with oil level - Relief valve set to 100 bar (to be set from 25 to 350 bar) - External pump GH-HPM20 for manual operation - Unstable 0-1 knob normally closed with lever for activation of the pump - Special knob - For double effect cylinders - Vertical mounting
  • POMPA "UPW-2,50-ACW-GR1-ELCD-VBO" FR-EXT - 200 bar
    AEL-UU-6125
    Pompa INGRANAGGI ELICOIDALI per "UPW" Gruppo 1 - Cilindrata 2,5 cc3/rev. - Aspirazione Posteriore 3/8"G - 200 bar - Max. 6000 rpm - Corpo centrale e coperchi in alluminio.
  • POMPA "SAE-A-9TH16/32-08,10-ACW-00-G2-GB-LT-LT"
    AEM-2F-9208
    Pompa ad ingranaggi GR2 - Rotazione antioraria ACW - Cilindrata 8,2 cc/rev. - Pressione massima 250 bar - V.max 3500 rpm - Corpo centrale in alluminio - Fondello e Flangia in alluminio tipo SAE-A con 2 fori D=11mm - Int.=106,2mm - Diametro centraggio D=82,55mm. Albero 9TH 16/32 DP FLAT ROOT - Attacchi laterali INLET 1/2"G - OUTLET 1/2"G
  • POMPA "SAE-A-9TH-G2-11,0+G2-11,0+00-00,0-CW-GB-LT
    AEM-2F-9611
    Pompa ad ingranaggi - DOPPIO STADIO - SAE-A-9TH-G2-11,0+G2-11,0 - Rotazione oraria CW - Pressione massima 200 bar - V.max 2000 rpm - Corpo centrale in alluminio - Fondello e Flangia in GHISA tipo SAE-A con 2 fori D=11mm - Int.=106,2mm - Diametro centraggio D=82,55mm. Albero 9TH 16/32 DP FLAT ROOT - Attacchi laterali FILETTO GAS (BSP) - INLET foro 1/2"G - OUTLET foro 1/2"G.
  • POMPA "UPW-01,00-ACW-ANT-TD-G1-GB-LT-LT-00-TD-GR1"
    AEM-UF-7110
    Pompa ad ingranaggi GR1 Flangia per MINICENTRALINA UPW Predisposta posteriormente per TANDEM-GR1 - Rotazione antioraria ACW - Portata 1,0 cc/rev. - Pressione massima 250 bar - V.max 3500 rpm - Corpo centrale e fondello in alluminio - Flangia in alluminio fori attacco D=8,5mm - Int.=40x40 - Diametro centraggio D=32 f7. Albero D=12 A PENNA - Attacchi laterali - IN 3/8"G - OUT 3/8"G
  • POMPA "UPW-01,60-ACW-ANT-TD-G1-GB-LT-LT-00-TD-GR1"
    AEM-UF-7116
    Pompa ad ingranaggi GR1 Flangia per MINICENTRALINA UPW Predisposta posteriormente per TANDEM-GR1 - Rotazione antioraria ACW - Portata 1,6 cc/rev. - Pressione massima 250 bar - V.max 3500 rpm - Corpo centrale e fondello in alluminio - Flangia in alluminio fori attacco D=8,5mm - Int.=40x40 - Diametro centraggio D=32 f7. Albero D=12 A PENNA - Attacchi laterali - IN 3/8"G - OUT 3/8"G
  • POMPA "UPW-1,50-ACW-GR0-AL" LATERAL-EXIT - 175 bar
    AEM-UO-0015
    Pompa per "UPW" Gruppo 0 - Cilindrata 1,50 cc3/rev. - Aspirazione Posteriore 1/4"G - 175 bar - Mandata Laterale 1/4"G - Max. 2500 rpm - Corpo centrale e coperchi in alluminio.
  • POMPA "UPW-4,80-ACW-00-G1-PW-PT-FR-00" - 260 bar
    AEM-UU-0148
    Pompa per "UPW" Gruppo 1 - Rotazione ANTIORARIA - Cilindrata 4,79 cc3/rev. - Aspirazione Posteriore 3/8"G - 260 bar - Max. 4000 rpm - Corpo centrale alluminio - Coperchi in ghisa.
  • POMPA "UPW-6,20-ACW-00-G1-PW-PT-FR-00" - 230 bar
    AEM-UU-0162
    Pompa per "UPW" Gruppo 1 - Rotazione ANTIORARIA - Cilindrata 6,20 cc3/rev. - Aspirazione Posteriore 3/8"G - 230 bar - Max. 3200 rpm - Corpo centrale alluminio - Coperchi in ghisa.
  • POMPA "UPW-7,30-CW-00-G1-PW-PT-FR-00" - 170 bar
    AEM-UU-1173
    Pompa per "UPW" Gruppo 1 - Rotazione ORARIA - Cilindrata 7,3 cc3/rev. - Aspirazione Posteriore 3/8"G - 170 bar - Max. 4000 rpm - Corpo centrale alluminio.
  • POMPA "EUR-04,50-CW-INT-TD-G2-EU-LT-LT-G2-TD-G2"
  • POMPA "EUR-06,30-CW-INT-TD-G2-EU-LT-LT-G2-TD-G1"