- ADT-RR-0415CAMMA per DISTRIBUTORE P040 - SPOOL CONTROL - 4 POSIZIONI "3-1-0-2" - "3" STABILE ( RITENUTA ) - "1" STABILE ( RITENUTA ) - "0" STABILE ( RITENUTA ) - "2" STABILE ( RITENUTA ) - Va accoppiato con IL CURSORE "K"
- ADT-RR-0416CAMMA per DISTRIBUTORE P040 - SPOOL CONTROL - 4 POSIZIONI "3-1-0-2" - "3" STABILE ( RITENUTA ) - "1" INSTABILE ( ritorno a MOLLA ) - "0" STABILE ( RITENUTA ) - "2" INSTABILE ( ritorno a MOLLA ) - Va in accoppiamento con SPOOL "K"
- ADT-RR-0801CAMMA per DISTRIBUTORE P040 - SPOOL CONTROL - 3 POSIZIONI "1-0-2" - "1" INSTABILE ( ritorno a MOLLA ) - "0" STABILE ( RITENUTA ) - "2" INSTABILE ( ritorno a MOLLA )
- ADT-RR-0802CAMMA per DISTRIBUTORE P040 - SPOOL CONTROL - 3 POSIZIONI "1-0-2" - "1"STABILE ( RITENUTA ) - "0" STABILE ( RITENUTA ) - "2" INSTABILE ( ritorno a MOLLA )
- ADT-RR-0803CAMMA per DISTRIBUTORE P040 - SPOOL CONTROL - 3 POSIZIONI "1-0-2" - "1" INSTABILE ( ritorno a MOLLA ) - "0" STABILE ( RITENUTA ) - "2" STABILE ( RITENUTA )
- ADT-RR-0808Control spool for distributor valve P080 - 3 POSITIONS "1-0-2" - "1" STABLE (detent) - "0" STABLE (detent) - "2" STABLE (detent)
- ADT-RR-0812CAMMA per DISTRIBUTORE P040 - SPOOL CONTROL - 4 POSIZIONI "1-0-2-3" - "1" INSTABILE ( ritorno a MOLLA ) - "0" STABILE ( RITENUTA ) - "2" INSTABILE ( ritorno a MOLLA ) - "3" STABILE ( RITENUTA ) - Va in accoppiamento con SPOOL "L"
- ADT-RR-5408CAMMA per DISTRIBUTORE P040 - SPOOL CONTROL - 3 POSIZIONI "1-0-2" - "1" STABILE ( RITENUTA ) - "0" STABILE ( RITENUTA ) - "2" STABILE ( RITENUTA )
- ADT-RS-0204Cursore per DISTRIBUTORE B020 - Configurazione "D" - 3 POSIZIONI - "PCYT" - Centro ad "Y" con "P" chiuso ed "A" e "B" in "T" ed "N" aperto - POSIZIONE-SX: Parallelo, "N" chiuso - POSIZIONE-DX: Incrociato, "N" chiuso.
- ADT-RS-0401Cursore per DISTRIBUTORE P040 - Configurazione "A" - 3 POSIZIONI - "PCCT" - Centro Chiuso con "N" aperto - POSIZIONE-SX: Parallelo, "N" chiuso - POSIZIONE-DX: Incrociato, "N" chiuso.
- ADT-RS-0402SPOOL for distributor valve P040 - Configuration "B" - 3 positions - "PCCT" - Closed Center with "N" open - POSITION-SX: "P" and "B" closed, "A" to "T", "N" open - POSITION-DX: "T" and "B" closed, "P" to "A", "N" closed.
- ADT-RS-0403SPOOL for DISTRIBUTOR P040 - Configuration "C" - 3 POSITIONS - "PCCT" - Closed Center with "N" open - POSITION-SX: "A" and "T" closed, "P" into "B", "N" closed - POSITION-DX: "P" and "A" closed "B" in "T", "N" open.
- ADT-RS-0404SPOOL for distributor valve P040 - Configuration "D" - 3 positions - "PCYT" - Center to "Y" with "P" closed and "A" and "B" in "T" and "N" open - POSITION SX: Parallel , "N" closed - DX-POSITION: Crossed, "N" closed.
- ADT-RS-0405Cursore per DISTRIBUTORE P040 - Configurazione "E" - 3 POSIZIONI - "PCBT" - Centro con "P" ed "A" chiusi e "B" in "T" ed "N" aperto - POSIZIONE-SX: Parallelo, "N" chiuso - POSIZIONE-DX: Incrociato, "N" chiuso.
- ADT-RS-0417Cursore per DISTRIBUTORE P040 - Configurazione "K" - 4 POSIZIONI - "PCCT" - Centro Chiuso con "N" aperto - IV POSIZIONE-SX: Centro ad "Y" con "P" chiuso ed "N" Aperto - POSIZIONE-SX: Parallelo, "N" chiuso - POSIZIONE-DX: Incrociato, "N" chiuso.