Articoli

Articles in page:
L_Catalogo_Visualizza:
  • RADIOCOMANDO "UPW-02CH-SPDR-NBL" 12/24V SPIDER *
    APA-R1-1800
    Remote control UPW-SPIDER 2 Channel - CONNECTION WITH SUPPORTING MODERATE (a signal every 100ms) ONE-WAY TO THE RECEIVER - Panel with 2 buttons UP - DOWN + 2 START - STOP + Warning lights Charge and Transmission. The receiver unit automatically goes into BLOCK (EMERGENCY) if the signal of the button (transmitter) is not present for more than 600 ms.
  • RADIOCOMANDO "UPW-02CH-0000-NBL" 12/24V BASE *
    APA-R1-1801
    Remote control UPW--NBL 2-channel - CONNECTION WITH SUPPORTING MODERATE (a signal every 100ms) ONE-WAY TO THE RECEIVER - Panel with 2 buttons UP - DOWN + 2 START - STOP + Warning lights Charge and Transmission. The receiver unit automatically goes into BLOCK (EMERGENCY) if the signal of the button (transmitter) is not present for more than 600 ms.
  • RADIOCOMANDO "UPW-02CH-0000-EAY" 12/24V *
    APA-R1-1802
    Remote control 2-channel - CONNECTION WITH SUPPORTING MODERATE (a signal every 100ms) ONE-WAY TO THE RECEIVER - Panel with 2 buttons UP - DOWN + 2 START - STOP + Warning lights Charge and Transmission. The receiver unit automatically goes into BLOCK (EMERGENCY) if the signal of the button (transmitter) is not present for more than 600 ms.
  • RADIOCOMANDO "UPW-04CH-0000-EAY" 12/24V *
    APA-R1-1804
    Remote control 4-channel - CONNECTION WITH SUPPORTING MODERATE (a signal every 100ms) ONE-WAY TO THE RECEIVER - Panel with 4 buttons 1, 2, 3, 4 + 2 START - STOP + Warning lights Charge and Transmission. The receiver unit automatically goes into BLOCK (EMERGENCY) if the signal of the button (transmitter) is not present for more than 600 ms.
  • RADIOCOMANDO "UPW-04CH-SPDR-EAY" 12/24V SPIDER *
    APA-R1-1805
    Remote control - 4-channel - CONNECTION WITH SUPPORTING MODERATE (a signal every 100ms) ONE-WAY TO THE RECEIVER - Panel with 4 buttons UP - DOWN - SX - DX + 2 buttons START - STOP + Warning lights Charge and Transmission. The receiver unit automatically goes into BLOCK (EMERGENCY) if the signal of the button (transmitter) is not present for more than 600 ms. Spider connector SICMA24.
  • RADIOCOMANDO "UPW-06CH-0000-EAY" 12/24V *
    APA-R1-1806
    Remote control 6-channel - CONNECTION WITH SUPPORTING MODERATE (a signal every 100ms) ONE-WAY TO THE RECEIVER - Panel with 6 buttons 1,2,3,4,5,6 + 2 START - STOP + Warning lights Charge and Transmission. The receiver unit automatically goes into BLOCK (EMERGENCY) if the signal of the button (transmitter) is not present for more than 600 ms.